Promising laboratory results had been shown for the reductive chemistry of a proprietary organic chemical. The process involved reacting a highly flammable ternary mixture with hydrogen to form selective product. Continuous operation was demonstrated yielding 90% conversion and 95+ % selectivity for 24 hrs of operation in the client's laboratory. ActiveSite was contacted to demonstrate performance in a 30X pilot asset.
A + B + C -> D (in solvent)
The unique handling requirements of the reaction mixture required upgrading the ActiveSite piloting facility. This involved the addition of 3 process vessels, reactor, utilities, and supporting infrastructure for Class 1 Div 2 operation. Upgrades were completed on an accelerated 6-week timeline
Results:
Direct replication of the laboratory conditions using a 30X scaled reactor resulted in an activity of 20% conversion and 10% selectivity which were significantly lower than the 80% conversion and 95% selectivity previously shown using the same catalyst, Figure 1 & 2. A series of process optimization experiments increased start of run (SOR) performance to 80% conversion and 98+% selectivity and steady state performance to 40% conversion and 98+% selectivity. Steady state stability at optimum conditions were demonstrated for 72 hours of unperturbed operation.
Figure 1: Comparison of catalyst activity for lab data using powdered catalyst and scale-up data using fixed bed catalyst. Lab data (black), Bench data at lab conditions (Blue), optimized bench conditions (Red).
Figure 2: Comparison of catalyst selectivity for lab data using powdered catalyst and scale-up data using fixed bed catalyst. Lab data (black), Bench data at lab conditions (Blue), optimized bench conditions (Red).
Further investigation including a comparison of 3rd party fixed bed catalysts indicated similar steady state results. It was determined that deactivation was not observed in the laboratory due to the high volume of active surface area for powdered catalysts relative to the timescales studied. A commercial reactor will contain 1000X less active metal surface area using a scalable fixed bed support. Lab studies would need to have run for over 40,000 hrs to observe the same deactivation at bench scale.
This study illustrates the importance of co-current lab and pilot development whereby lab experiments are used to prescreen ideas than validate the best performers at pilot scale where heat & mass transfer effects become relevant. This model is highly efficient for bringing new chemicals to market and mitigates the risk of direct scaleup to commercial volumes from lab results. Contact ActiveSite for more information on how we can help scale your chemistry.